Abstract:Aortic valve replacement (AVR) is generally accepted as the standard operation to treat symptomatic aortic valvular diseases now.AVR can apparently improve the clinical symptoms and hemodynamics of patients with aortic valve stenosis or regurgitation.AVR has good effect and a higher long-term survival rate. Although transcatheter aortic valve implantation (TAVI) has also been accepted as an effective means to treat aortic valvular diseases,AVR is still the most reliable surgical procedure.Echocardiography is the most important method to diagnose aortic valve stenosis or regurgitation.Echocardiography is also a safe and reliable non-invasive detecting technique,which has important value on having preoperative evaluation,determining operation indication,choosing operation procedure and judging prognosis.The early complications of AVR affect the prognosis of patients after the surgery.Echocardiography is the most widely used clinical methodology for detecting the early complications that occurred within 30 days after the surgical procedure of AVR.Conventional echocardiography is most widely used,but new echocardiographic techniques such as tissue Doppler imaging(TDI),two-dimensional or three-dimensional speckle tracking imaging (2D or 3D-STI) and stress echocardiography are getting more and more attentive in recent years.However,there isn't enough sufficient evidence to prove the predictive value of echocardiography on early complications after AVR.This article reviewed echocardiographic detective Methods of main early complications after AVR,which may provide evidence to study the predictive value of preoperative echocardiographic index on early postoperative complications.
[1]Tjang YS, van Hees Y, KÖrfer R, et al. Predictors of mortality after aortic valve replacement[J]. Eur J Cardiothorac Surg,2007,32 (3):469-474. [2]Saxena A, Poh CL, Dinh DT, et al. Early and late outcomes after isolated aortic valve replacement in octogenarians: an Australasian Society of Cardiac and Thoracic Surgeons Cardiac Surgery Database Study[J].Eur J Cardiothorac Surg,2012,41(1):63-68. [3]Hernández-Vaquero D,Llosa JC,Díaz R,et al. Impact of patient-prosthesis mismatch on 30-day outcomes in young and middle-aged patients undergoing aortic valve replacement[J].J Cardiothorac Surg,2012,15(7):46. [4]Urso S, Sadaba R, Aldamiz-Echevarria G. Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement[J].Interact Cardiovasc Thorac Surg,2009,9(3):510-518. [5]Calvo D,Lozano I,Llosa JC,et al.Aortic valve replacement in octogenarians with severe aortic stenosis. Experience in a series of consecutive patients at a single center[J]. Rev Esp Cardiol,2007,60(7):720-726. [6]Di Eusanio M,Fortuna D,Cristell D,et al.Contemporary outcomes of conventional aortic valve replacement in 638 octogenarians:insights from an Italian Regional Cardiac Surgery Registry (RERIC)[J].Eur J Cardiothorac Surg,2012,41(6):1247-1252. [7]Nicolini F, Beghi C, Barbieri F, et al. Aortic valve replacement in octogenarians: analysis of risk factors for early and late mortality[J]. J Heart Valve Dis,2010,19(5):615-622. [8]Kim TH,Park KH,Yoo JS,et al.Does additional aortic procedure carry a higher risk in patients undergoing aortic valve replacement[J].Korean J Thorac Cardiovasc Surg,2012,45(5):295-300. [9]Bang JH, Kim JW, Lee JW, et al. Minimally invasive approaches versus conventional sternotomy for aortic valve replacement: a propensity score matching study[J].Korean J Thorac Cardiovasc Surg,2012,45(2):80-84. [10] MØlstad P,Veel T,Rynning S.Long-term survival after aortic valve replacement in octogenarians and high-risk subgroups[J].Eur J Cardiothorac Surg,2012,42(6):934-940. [11]Rahimtoola SH.The problem of valve prosthesis-patient mismatch[J].Circulation,1978,58(1):20-24. [12]Pibarot P,Dumesnil JG.Prosthesis-patient mismatch:definition,clinical impact and prevention[J].Heart,2006,92(8):1022-1029. [13]Bleiziffer S, Eichinger WB, Hettich I, et al. Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement:which is the best method[J].Heart,2007,93(5):615-620. [14]Farias FR,da Costa FD,Balbi Filho EM,et al.Aortic valve replacement with the Cardioprotese Premium bovine pericardium bioprosthesis: four-year clinical results[J].Interact Cardiovasc Thorac Surg,2012,15(2):229-234. [15]Patanè F,Sansone F,Campanella A,et al.Acute bioprosthetic thrombosis immediately after aortic valve replacement[J].J Cardiovasc Med (Hagerstown),2009,10(2):167-169. [16]Ingvarsdóttir IL, Viktorsson SA, Hreinsson K, et al. Aortic valve replacement for aortic stenosis in Iceland 2002-2006: Indications and short term complications[J].Laeknabladid,2011,97(10):523-527. [17]Bach DS. Echo/Doppler evaluation of hemodynamics after aortic valve replacement: principles of interrogation and evaluation of high gradients[J].JACC Cardiovasc Imaging,2010,3(3):296-304. [18]Citro R, Bossone E, Kuersten B, et al. Tissue Doppler and strain imaging:anything left in the echo-lab[J].Cardiovasc Ultrasound,2008,30(6):54. [19]Norrild K, Pedersen TF, Sloth E. Transesophageal tissue Doppler echocardiography for evaluation of myocardial function during aortic valve replacement[J].J Cardiothorac Vasc Anesth,2007,21(3):367-370. [20]Bauer F,Mghaieth F,Dervaux N,et al.Preoperative tissue Doppler imaging differentiates beneficial from detrimental left ventricular hypertrophy in patients with surgical aortic stenosis[J].A postoperative morbidity study,Heart,2008,94(11):1440-1445. [21]Poh KK,Chan MY,Yang H,et al.Prognostication of valvular aortic stenosis using tissue Doppler echocardiography: underappreciated importance of late diastolic mitral annular velocity[J].J Am Soc Echocardiogr,2008,21(5):475-481. [22]Helle-Valle T,Crosby J,Edvardsen T,et al.New noninvasive method for assessment of left ventricular rotation:speckle tracking echocardiography [J].Circulation,2005,112 (20):3149-3156. [23]王斌,洪涛,程蕾蕾.应变及应变率显像在瓣膜病患者心功能评价中的应用进展[J].中华胸心血管外科杂志,2012,28(8):500-503. [24]Ohara Y, Fukuoka Y, Tabuchi I, et al. The impairment of endocardial radial strain is related to aortic stenosis severity in patients with aortic stenosis and preserved LV ejection fraction using two-dimensional speckle tracking echocardiography[J].Echocardiography,2012,11. [25]Altekin RE, Kucuk M, Yanikoglu A, et al. Evaluation of the left ventricular regional function using two-dimensional speckle tracking echocardiography in patients with end-stage renal disease with preserved left ventricular ejection fraction[J].Acta Cardiol,2012,67(6):681-691. [26]Pirat B,McCulloch ML,Zoghbi WA.Evaluation of global and regional right ventricular systolic function in patients with pulmonary hypertension using a novel speckle tracking method [J]. Am J Cardiol, 2006, 98(5):699-704. [27]Petko C,Hoffmann U,MÖller P,et al.Assessment of ventricular function and dyssynchrony before and after stage 2 palliation of hypoplastic left heart syndrome using two-dimensional speckle tracking[J].Pediatr Cardiol,2010,31(7):1037-1042. [28]Zhang Q,Fung JW,Yip GW,et al.Improvement of left ventricular myocardial short-axis,but not long-axis function or torsion after cardiac resynchronisation therapy:an assessment by two-dimensional speckle tracking[J].Heart,2008,94(11):1464-1471. [29]Norisada K,Kawai H,Tanaka H,et al.Myocardial contractile function in the region of the left ventricular pacing lead predicts the response to cardiac resynchronization therapy assessed by two-dimensional speckle tracking echocardiography[J].J Am Soc Echocardiogr,2010,23(2):181-189. [30]Abhayaratna WP, Fatema K, Barnes ME,et al. Left atrial reservoir function as a potent marker for first atrial fibrillation or flutter in persons > or = 65 years of age[J].Am J Cardiol,2008,101(1):1626-1629. [31]Cianciulli TF,Saccheri MC,Lax JA,et al.Two-dimensional speckle tracking echocardiography for the assessment of atrial function[J].World J Cardiol,2010,2(7):163-170. [32]Cimino S,Canali E,Petronilli V,et al.Global and regional longitudinal strain assessed by two-dimensional speckle tracking echocardiography identifies early myocardial dysfunction and transmural extent of myocardial scar in patients with acute ST elevation myocardial infarction and relatively preserved LV function[J].Eur Heart J Cardiovasc Imaging,2013,14(8):805-811. [33]Biswas M,Sudhakar S,Nanda NC,et al.Two-and three-dimensional speckle tracking echocardiography: clinical applications and future directions[J].Echocardiography,2013,30(1):88-105. [34]Schueler R, Sinning JM, Momcilovic D, et al. Three-dimensional speckle-tracking analysis of left ventricular function after transcatheter aortic valve implantation[J].J Am Soc Echocardiogr,2012,25(8):827-834. [35]Kang Y,Sun MM,Cui J,et al.Three-dimensional speckle tracking echocardiography for the assessment of left ventricular function and mechanical dyssynchrony[J].Acta Cardiol, 2012,67(4):423-430. [36]Onishi N,Kawasaki M,Tanaka R,et al.Comparison between left atrial features in well-controlled hypertensive patients and normal subjects assessed by three-dimensional speckle tracking echocardiography[J].J Cardiol,2013,9(6). [37]Li CM, Li C, Bai WJ, et al. Value of three-dimensional speckle-tracking in detecting left ventricular dysfunction in patients with aortic valvular diseases[J].J Am Soc Echocardiogr,2013,26(11):1245-1252. [38]Zhu W,Liu W,Tong Y,et al.Three-dimensional speckle tracking echocardiography for the evaluation of the infarct size and segmental transmural involvement in patients with acute myocardial infarction[J].Echocardiography,2014,31(1):58-66. [39]Yang Y, Sun JP, Fang F, et al. Two-dimensional speckle-tracking echocardiography is more accurate than tissue Doppler imaging in assessing regional atrial deformation: a study in patients after transcatheter atrial septal defect closure[J]. Int J Cardiol,2012,162(1):64-65. [40]Ng AC,Tran da T,Newman M,et al.Comparison of left ventricular dyssynchrony by two-dimensional speckle tracking versus tissue Doppler imaging in patients with non-ST-elevation myocardial infarction and preserved left ventricular systolic function[J].Am J Cardiol,2008,102(9):1146-1150. [41]Fontana A, Zambon A, Cesana F, et al. Tissue Doppler, triplane echocardiography,and speckle tracking echocardiography:different ways of measuring longitudinal myocardial velocity and deformation parameters.A comparative clinical study[J].Echocardiography,2012,29(4):428-437. [42]Clavel MA, Fuchs C, Burwash IG, et al. Predictors of outcomes in low-flow, low-gradient aortic stenosis: results of the multicenter TOPAS study[J].Circulation,2008,118 (14):234-242. [43]Levy F, Laurent M, Monin JL, et al. Aortic valve replacement for lowflow / lowgradient aortic stenosis operative risk stratification and long term outcome: a European multicenter study[J].J Am Coll Cardiol,2008, 51(15):1466-1472. [44]潘祥林,王鸿利.诊断学的任务与发展方向[J].中华诊断学电子杂志,2013,1(1):8-9. [45]王少春,陈东风,胡军利,等.经食管超声心动图在先天性心脏病创伤性治疗中的临床应用价值[J].济宁医学院学报,2011,34(3):172-175.